ACE Salt Water Sanitizing System Page 13
1. Press Mode until the ACE menu appears, followed by pressing the On button.
2. Scroll to SALT menu by pressing the Mode button. In the SALT menu, press the Off
button twice to select and confirm the Salt Test. The water care icon will flash to
indicate that the setting has been updated. The SALT menu item will
flash while the system is testing. Do not attempt to conduct a Salt Test
while the jets are running
3. When the test is complete the menu will display one of the following:
a. SALT 1 - 2 : salt low (SALT menu item will flash)
b. SALT 3 - 6 : salt in range (target 4 or 6)
c. SALT 7 - 9 : salt high (SALT menu item will flash)
4. If “Low Salt” or “High Salt” is displayed, proceed as follows:
POSSIBLE CAUSES OF A LOW SALT READING
: The salt
level reading can be affected by cell age, scale build-up (dirty cell), cold water, high
chlorine dirty filters, or dirty water
(do not add salt until the previous conditions
have been inspected)
.
A salt test strip or meter can be used to manually
verify the system’s salt level reading before adding additional salt.
For Low Salt –
1. Verify the actual salt level of the water using the salt test strips
included with your ACE system.
2. If the reading on the test strip confirms that the salt level of the
water is low add (1) cup of salt to the water and circulate for 5
minutes. Activate a second salt test.
3. If 50% of the spa’s recommended salt has been added or the
salt indication has not moved and the icon continues to flash,
contact your Hot Spring Service Professional for assistance.
For High Salt –
1. Drain 25-50% of the water, depending on the salt level reading,
from the spa and refill with clean, clear water.
2. If the water is more than 6 months old, drain completely and refill
following the Start-up and Refill Procedure.
3. Run the jet pumps for 5 minutes, then conduct another manual
Salt Test.
4. If the proper amount of salt is present, the screen will display
SALT 4-6 and the water care icon will be solid. If the screen still
displays High Salt 7-9, repeat steps as needed.
Limelight
®
Hot Tubs Operation Page 13
Salt Level
9
8
7
6
5
4
3
2
1
Low
High
OK
Target
{

Other manuals for HotSpring ACE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HotSpring ACE and is the answer not in the manual?

HotSpring ACE Specifications

General IconGeneral
BrandHotSpring
ModelACE
CategoryWater Filtration Systems
LanguageEnglish