No terminal display
The configuration terminal has no display when the switch is powered on.
To resolve the problem:
1. Verify that the power system is operating correctly.
2. Verify that the console cable has been connected correctly and no fault occurs on the console
cable.
3. Verify that the following settings are configured for the terminal:
{ Baud rate9600.
{ Data bits—8.
{ Stop bits—1.
{ Parity—None.
{ Flow control—None.
4. If the problem persists, contact Hewlett Packard Enterprise Support.
Garbled terminal display
The configuration terminal displays garbled text.
To resolve the problem:
1. Verify that the following settings are configured for the terminal:
{ Baud rate9600.
{ Data bits—8.
{ Stop bits—1.
{ Parity—None.
{ Flow control—None.
2. If the problem persists, contact Hewlett Packard Enterprise Support.