20
Version KA.15.10.0003
Status: Released, but removed from the web due to CR_0000124276.
This software is recalled and no longer recommended.
BootROM (CR_0000119469) - This software version includes a BootROM update to BootROM version KA.15.09.
Crash (CR_0000114674) - A stack member might reboot unexpectedly with a message similar to the following,
after the user enters the command show tech stacking member X where X is not the commander number.
Restr Mem Access
HW Addr=0xfee81fb0 IP=0xa2f26b8 Task='muiCtrl' Task ID=0x3c939780
sp:0x125aa2a0 lr:0xa2f2358
msr: 0x02029200 xer: 0x00000000 cr: 0x24000800
Crash (CR_0000116647) - It is possible for the switch to reboot unexpectedly with a message similar to the
following.
Software exception in kernel context at ghsException.c:1101
-> Internal system error
Crash (CR_0000116912) - With OSPF routing and MSTP enabled, it is possible for the switch to reboot unexpectedly
with a message similar to the following.
Software exception at rt_table.c:4453 -- in 'eRouteCtrl', task ID = 0xa95e140
-> Routing Stack: Assert Failed
Crash (CR_0000118474) - The switch experiences a gradual loss of free memory when clients that use a RADIUS-
assigned ACL reauthenticate. This can cause the switch to reboot unexpectedly.
Distributed Trunking (CR_0000103240) - With Distributed Trunking enabled, applying the command clear mac-
address to the VLAN of the InterSwitch-Connect (ISC) on one switch can cause the peer switch to drop packets that
should be forwarded across the ISC.
Distributed Trunking (CR_0000115557) - Multicast hosts might be temporarily dropped from the multicast
stream, in a topology with Distributed Trunking where a Group-Specific Host Membership Query should be forwarded
across the Inter-Switch Connection (ISC).
Distributed Trunking (CR_0000118526) - In a switch-to-switch Distributed Trunking topology with IGMP enabled,
multicast streams learned on one Distributed Trunking switch might not be known to the other Distributed Trunking
switch. The result is multicast streams that cannot be joined by clients on one switch.
Distributed Trunking (CR_0000118663) - The standby switch periodically reports Out of pkt buffers,on
a stack with redundant management configured for Distributed Trunking. This can lead to an unexpected reboot of
the standby switch.
Enhancement (PR_0000073100, CR_0000077888) - This feature provides SNMP read access to the CPU
utilization of the modules. Currently the only method to retrieve the module CPU utilization is the CLI command show
cpu slot <slot | all>. A new MIB table is created to facilitate the reading of information related to the module and its
CPU utilization statistics.
Enhancement (CR_0000103497) - When using Commands authorization, the Web Agent windows may show or
hide fields, or allow or deny configuration steps, based on the access or deny list (VSA filtering) for the authenticated
user. For more information, see the chapter "RADIUS Authentication, Authorization, and Accounting" in the Access