■ Crash (CR_0000126799) - Under unusual stress conditions, the switch might reboot unexpectedly with a message
similar to
Software exception at fileTransfer.c:1144 -- in 'tHttpd', task ID = 0xa9389c0 -> Could
not open file.
■ DHCP Snooping (CR_0000126311) - The CLI entry dhcp-snooping option 82 untrusted-policy keep is not included in
the config file if no dhcp-snooping option 82 is also configured. If the config file is saved to a TFTP server, it will not
function properly when subsequently loaded on a switch.
■ Distributed Trunking (CR_0000124473) - The switch does not allow DHCP server responses to cross the Inter-
Switch Connection (ISC).
■ Distributed Trunking (CR_0000125623) - After rebooting a switch participating in a distributed LACP trunk, a
distributed trunk port that is disconnected will not link after it is connected.
■ Distributed Trunking (CR_0000127096) - When the Inter-Switch Connection (ISC) is brought down, clients
connected via Distributed Trunk links cannot be reached from one of the Distributed Trunking switches.
■ Include Credentials (CR_0000127700) - With include credentials enabled, a config file that is saved to a TFTP
server does not contain the SNMPv3 credentials.
■ LEDs (CR_0000115489) - After a PoE error is resolved, the switch turns off the PoE LED but continues to flash the
Fault LED.
■ OSPF (CR_0000122980) - OSPF3 ECMP routes are not displayed in the IPv6 route table.
■ Policy Based Routing (CR_0000125847) - After configuring a policy and applying it to a VLAN, the IP next-hop is
unreachable until the switch is rebooted.
■ Routing (CR_0000123230) - The switch does not forward traffic to a host that has a static route configured with a
32-bit subnet mask. Traces show that the switch never sends an ARP request for that host.
■ Routing (CR_0000128007) - ARP replies from a Microsoft Network Load Balancing (NLB) cluster operating in
multicast mode cause the switch to use software routing. This affects v2 zl modules and 3800 switches.
■ sFlow (CR_0000128567) - The switch uses the IP address of the source VLAN as the sFlow packet source, instead
of the configured source-interface.
■ SNMP (CR_0000122623) - After rebooting a switch configured for SNMP with the parameters operator unrestricted,
the switch does not allow the user to set any read/write MIB objects.
■ SNMP (CR_0000125513) - The value stored in MIB object ospfNbrState (OID 1.3.6.1.2.1.14.10.1.6) is incorrect.
■ Transceivers (CR_0000126801) - After booting a 3800 switch or a K-software switch with a v2 zl module, a J9054B/
C 100-FX SFP-LC transceiver that was already inserted (or is inserted during the boot process) will not link with the
remote end.
■ Web Management (CR_0000125239) - After logging into the switch Web user interface, closing the tab on some
Web browsers does not log the user out of the Web session.
Version KA.15.10.0010
Status: Released, but no longer recommended due to CR_0000127868.
The following problems were resolved in software version KA.15.10.0010.
■ IGMP (CR_0000127628) - In a topology where the host connects to a querier, the querier connects to a non-querier
switch, the non-querier switch connects to a router, and the multicast source is beyond the router, the host might not
receive the multicast stream. This happens because a "join" from the host that is received by the querier is not
forwarded by the non-querier switch.