B Specifications
Temperature Range
Operating
Nonoperating
50° to 95°F
-22° to 140°F
10° to 35°C
-30° to 60°C
NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct
sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options
installed.
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
10-90%
5-95%
10-90%
5-95%
Maximum Altitude (unpressurized)
Operating
Nonoperating
10,000 ft
30,000 ft
3048 m
9144 m
Power Supply
180W
Rated Line Frequency 50-60 Hz
Operating Line Frequency 47-63 Hz
1
This system utilizes an active power factor corrected power supply. This allows the system to pass the CE mark requirements for use
in the countries of the European Union. The active power factor corrected power supply also has the added benefit of not requiring
an input voltage range select switch.
2
High efficiency power supply is a requirement for ENERGY STAR® qualification in conjunction with a select range of processors and
modules.
94 Appendix B Specifications

Table of Contents

Other manuals for HP RP2 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP RP2 2000 and is the answer not in the manual?

HP RP2 2000 Specifications

General IconGeneral
BrandHP
ModelRP2 2000
CategoryTouchscreen
LanguageEnglish

Related product manuals