511U Rackmount Tape Enclosure Reference Guide
C
Specifications
Table 3: HP StorageWorkds 1U Rackmount Tape Enclosure
Parameter English Metric
Dimensions
Height
Depth
Width
1.75 in
25.25 in
19.0 in
4.44 cm
64.1 cm
48.3 cm
Weight (1 drive installed) 20 lb 9.07 kg
Input power requirements
Rated input voltage
Rated input current
Rated input frequency
Input power (max)
90 to 264 VAC
2.4 A
47 - 63 Hz
140 W*
90 to 264 VAC
2.4 A
47 - 63 Hz
140 W*
Heat Dissipation (max) 478 BTU/hr* 478 BTU/hr*
Temperature range
Operating
Non-operating
41° to 104° F
-40° to 158° F
5° to 40° C
-40° to 70° C
Relative humidity
Operating (non-condensing)
Non-operating
20% to 80%
5% to 95%
20% to 80%
5% to 95%
Wet bulb temperature (max) 7 F 26° C
Altitude (max)
Operating
Non-operating
0 to 15,000 ft
0 to 50,000 ft
0 to 4600 m
0 to 15200 m
* Input power and Heat dissipation specifications are maximum values and apply to
worst-case conditions at full rated power supply load. The power/heat dissipation
for your installation will vary depending on the equipment configuration.