EasyManuals Logo
Home>Huawei>Switch>S5700 Series

Huawei S5700 Series Hardware Description

Huawei S5700 Series
253 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #103 background imageLoading...
Page #103 background image
Item Description
Operating
temperature
0°C to 50°C (32°F to 122°F) at an altitude of 0-1800 m (0-5096 ft.)
NOTE
When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating
temperature reduces by 1°C (1.8°F) every time the altitude increases by 220
m (722 ft.).
The operating temperature of the switch is 0°C to 45°C (32°F to 113°F) when
it uses SFP optical modules with 80 km or longer transmission distances.
Storage
temperature
-40°C to +70°C (-40°F to +158°F)
Noise under normal
temperature (27°C,
sound power)
Noise-free (no fans)
Relative humidity 5% to 95%, noncondensing
Operating altitude 0-5000 m (0-16404 ft.)
Certification
l EMC certification
l Safety certification
l Manufacturing certification
3.4.4 S5700-28P-LI-DC
Version Mapping
Table 3-19 lists the mapping between the S5700-28P-LI-DC chassis and software versions.
Table 3-19 Version mapping
Series
Model Software Version
S5700-LI S5700-28P-LI-DC V200R001C00 and later versions
NOTE
This model does not match V200R001C01,
V200R003C02, V200R003C10,
V200R005C00SPC500, V200R005C01,
V200R005C02, V200R005C03, or
V200R007C10.
S5700 Series Ethernet Switches
Hardware Description
3 Chassis
Issue 24 (2016-08-12) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
89

Table of Contents

Other manuals for Huawei S5700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei S5700 Series and is the answer not in the manual?

Huawei S5700 Series Specifications

General IconGeneral
BrandHuawei
ModelS5700 Series
CategorySwitch
LanguageEnglish

Related product manuals