Common Wire (Black Leads)
ENG
ATTACHING SOLENOIDS
The NODE-100 is provided with a solenoid attached to the
controller. The NODE-200, NODE-400, and NODE-600 multi-station
controllers will operate up to 2, 4, or 6 solenoids, respectively.
Hunter DC solenoids (P/N 458200) can easily be installed on all
Hunter Plastic Valves.
NOTE: Must use DC Latching Solenoids
operating between 9-11VDC. 24VAC Solenoids
will not operate with the NODE.
To Wire DC Solenoids to the NODE
1. Attach the black leads from each solenoid to the single
common wire (black lead) coming from the NODE. Secure all
wire connections with waterproof connectors.
2. Attach one red wire from each solenoid to the corresponding
station wire (red lead) from the NODE. The station numbers
are identied on the face of the NODE. Secure all wire
connections with waterproof connectors.
NOTE: The maximum wire distance between the
solenoid and NODE is 100 ft/30 m (18 gauge
minimum wire size).
Station Wire (Red Leads)
5