MAX200 Instruction Manual 4-7
OPERATION
9. Replace the electrode and tighten it with the wrench. Do not overtighten it.
10. Install the swirl ring with the bottom O-ring facing the inside of the torch - it won't fit in properly if it is installed in
the wrong direction. Push it into place.
11. Install the nozzle and finger-tighten it. Finish tightening it with the wrench. Do not overtighten it.
12. Replace the retaining cap. Make sure that it is tightened snugly; if it is loose, it can affect the shield gas flow.
Figure 4-2 Changing Consumable Parts
Shield NozzleRetaining Cap ElectrodeSwirl Ring