MAX200 Instruction Manual 4-23
9-99
OPERATION
PAC200T/PAC200E Hand Torch
Mild Steel
100 amps
O
2
Plasma / Air Shield
This gas combination gives good cut speed, low dross level and is very economical. Some surface
nitriding can occur. While this process may be used on thicker materials, optimal recommended range is to
3/8 inch (10 mm).
Piercing above 3/8 inch (10 mm) not recommended.
* If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
020919
Shield
020616
Nozzle
020915
Retaining cap
120547
Electrode
020617
Swirl ring
Plasma
Gas
Type
Plasma Gas
Pressure
TEST/RUN
Shield
Gas
Type
Shield
Gas
Pressure
Arc
Current
Setting
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Plasma
Gas Inlet
Pressure
Shield
Gas Inlet
Pressure
(Inches) (mm) (psi) (psi) (Inches) (mm) (amps) (volts) (ipm) (mm/min) (sec) (psi) (psi)
1/8 3
O
2
20-24* / 60-64 Air 60 5/64 2 100 110 210 5330 120 90
3/16 5 1/8 3 115 130 3300
1/4 6 1/8 3 115 100 2540 0.5
3/8 10 1/8 3 120 75 1900 0.5
1/2 12 1/8 3 120 62 1575
5/8 15 .158 4 130 45 1150
3/4 20 3/16 5 135 30 760
Material
Thickness
Torch-to-work
Distance
Travel Speed
(40 SCFH) (270 SCFH)

Table of Contents

Other manuals for Hypertherm MAX200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm MAX200 and is the answer not in the manual?

Hypertherm MAX200 Specifications

General IconGeneral
BrandHypertherm
ModelMAX200
CategoryWelding System
LanguageEnglish

Related product manuals