OPERATION
powermax
65/85
Operator Manual 4-15
Understanding duty-cycle limitations
The duty cycle is the amount of time, in minutes, that a plasma arc can remain on within a
10-minute period when operating at an ambient temperature of 104° F (40° C).
With a Powermax65:
At 65A, the arc can remain on for 5 minutes out of 10 minutes without causing the unit to
overheat (50% duty cycle).
At 59A, the arc can remain on for 6 minutes out of 10 (60%)
At 46A, the arc can remain on for 10 minutes out of 10 (100%).
With a Powermax85:
At 85A, the arc can remain on for 6 minutes out of 10 minutes without causing the unit to
overheat (60% duty cycle).
At 74A, the arc can remain on for 8 minutes out of 10 (80%)
At 66A, the arc can remain on for 10 minutes out of 10 (100%).
If the duty cycle is exceeded, the power supply overheats, the temperature fault icon appears in the
status screen, the arc shuts off, and the cooling fan continues to run. You can not resume cutting
until the temperature fault icon disappears and the fault LED goes off.

Table of Contents

Other manuals for Hypertherm Powermax 85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 85 and is the answer not in the manual?

Hypertherm Powermax 85 Specifications

General IconGeneral
BrandHypertherm
ModelPowermax 85
CategoryWelding System
LanguageEnglish

Related product manuals