MAINTENANCE AND REPAIR
5-6
powermax
65/85
Operator Manual
Fault codes and solutions
A label with descriptions for these common fault codes can be found inside the front cover of this
manual. Peel off the label and place it on the rear of the power supply for reference.
Fault
code
Description Power
LED
Fault
LED
Fault
icon
Solutions
0-12 Low input gas pressure:
Warning (the system
continues to operate)
On Off Adjust the gas inlet
pressure as needed.
0-13 AC input unstable:
Warning (the system
continues to operate)
Blink
fast
Off
Correct the power source.
0-20 Low gas pressure On On
Check the input gas
supply.
Adjust the gas pressure
to the acceptable range
using Manual mode. See
“Manually adjusting the
gas pressure” on page 4-13.
0-21 Gas flow lost while
cutting
On On
Restore the gas inlet
pressure and restart the
power supply.
Check the torch lead for
leaks or kinking.
0-22 No gas input On On
Connect the gas source
and restart the power
supply.

Table of Contents

Other manuals for Hypertherm Powermax 85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 85 and is the answer not in the manual?

Hypertherm Powermax 85 Specifications

General IconGeneral
BrandHypertherm
ModelPowermax 85
CategoryWelding System
LanguageEnglish

Related product manuals