OPERATION
powermax
65/85
Operator Manual 4-23
Common hand-cutting faults
The torch does not cut completely through the workpiece. The causes can be:
The cut speed is too fast.
The consumables are worn.
The metal being cut is too thick for the selected amperage.
Gouging consumables are installed instead of drag-cutting consumables.
The work clamp is not attached properly to the workpiece.
The gas pressure or gas flow rate is too low.
Cut quality is poor. The causes can be:
The metal being cut is too thick for the amperage.
The wrong consumables are being used (gouging consumables are installed instead of
drag-cutting consumables, for example).
You are moving the torch too quickly or too slowly.
The arc sputters and consumables life is shorter than expected. The cause can be:
Moisture in the gas supply.
Incorrect gas pressure.
Consumables incorrectly installed.