TORCH SETUP
3-46
powermax
65/85
Operator Manual
85A Unshielded Air flow rate - slpm/scfh
Aluminum
Hot 190 / 400
Cold 235 / 500
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm mm mm % seconds (mm/min) Volts (mm/min) Volts
2
2.0
5.0 250
0.1
8700 118 14000 115
3 7350 120 12000 116
4 0.2 6000 122 10000 117
6
0.5
3300 125 6150 119
8 2350 127 4100 121
10
6.0 300
0.5 1800 128 2650 124
12 0.7 1300 133 2160 127
16
Edge Start
840 139 1400 132
20 470 144 900 137
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in in % seconds ipm Volts ipm Volts
1/8 in
0.08
0.20 250
0.2
280 120 460 116
3/16 in 200 123 335 118
1/4 in
0.5
110 126 215 119
3/8 in 75 127 110 123
1/2 in 0.24 300 0.6 45 135 78 128
5/8 in
Edge Start
34 139 56 132
3/4 in 22 143 40 136

Table of Contents

Other manuals for Hypertherm Powermax 85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 85 and is the answer not in the manual?

Hypertherm Powermax 85 Specifications

General IconGeneral
BrandHypertherm
ModelPowermax 85
CategoryWelding System
LanguageEnglish

Related product manuals