Powermax125 Operator Manual 808080 Revision 0 33
2 Power Supply Setup
Extension cord recommendations
Any extension cord must have an appropriate wire size for the cord length and system voltage. Use a cord that meets
national and local codes.
For all Powermax125 configurations, the recommended gauge size for any three-phase extension cord between
3 45 m (10 150 feet) is 10 mm
2
(8 AWG).
Engine-driven generator recommendations
Generators used with the Powermax125 should satisfy the voltage requirements in the following table and in Hypertherm
power supply ratings on page 20.
Based on the generator rating, age, and condition, adjust the cutting current as needed.
If a fault occurs while using a generator, turning the power switch quickly to OFF and then
to ON again (sometimes called a “quick reset”) may not clear the fault. Instead, turn OFF
the power supply and wait 60 to 70 seconds before turning it ON again.
Engine drive rating System output current Performance (arc stretch)
40 kW 125 A Full
30 kW 125 A Limited
30 kW 100 A Full
25 kW 100 A Limited
22.5 kW 75 A Full
20 kW 75 A Limited
20 kW 60 A Full
15 kW 60 A Limited
12 kW 40 A Full
10 kW 40 A Limited
10 kW 30 A Full
8 kW 30 A Limited

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax125 and is the answer not in the manual?

Hypertherm Powermax125 Specifications

General IconGeneral
BrandHypertherm
ModelPowermax125
CategoryWelding System
LanguageEnglish

Related product manuals