Powermax125 Operator Manual 808080 Revision 0 91
6 Machine Torch Setup
45 A shielded cutting – mild steel
Air flow rate slpm/scfh
Hot 217 / 460
Cold 241 / 510
Metric
Material
Thickness
Torch-to-Work
Distance
Initial Pierce Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
mm mm mm % seconds mm/min volts mm/min volts
0.5
0.5 2.0 400
0.0
8890 118 12510 120
1 8890 119 10760 120
1.5 0.1 8040 123 10160 123
2
1.5 3.8 250
0.3 6565 128 7770 125
3
0.4
3725 129 4890 128
4 2250 130 3550 130
6 0.5 1265 132 2050 130
English
Material
Thickness
Torch-to-Work
Distance
Initial Pierce Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
inches inches inches % seconds ipm volts ipm volts
26 GA
0.02 0.08 400
0.0
350 118 500 120
22 GA 350 118 450 120
18 GA
0.1
350 119 400 120
16 GA 314 123 400 123
14 GA
0.06 0.15 250
0.2 270 128 320 125
12 GA
0.4
185 129 216 127
10 GA 100 130 164 130
3/16 0.5 74 131 108 130
1/4 0.6 43 132 73 130

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax125 and is the answer not in the manual?

Hypertherm Powermax125 Specifications

General IconGeneral
BrandHypertherm
ModelPowermax125
CategoryWelding System
LanguageEnglish

Related product manuals