88 Powermax125 Operator Manual 808080 Revision 0
6 Machine Torch Setup
65 A shielded cutting – stainless steel
Air flow rate slpm/scfh
Hot 222 / 470
Cold 250 / 530
Metric
Material
Thickness
Torch-to-Work
Distance
Initial Pierce Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
mm mm mm % seconds mm/min volts mm/min volts
2
1.5
3.8 250
0.1 7405 119 9970 121
3 0.2 6120 120 8240 122
4
0.5
4840 122 6110 123
6 2275 125 2840 125
8
0.7
1505 127 1860 127
10
4.5 300
1115 130 1245 128
12 1.2 720 133 925 130
16
Edge Start
465 137 505 136
20 320 141 345 141
English
Material
Thickness
Torch-to-Work
Distance
Initial Pierce Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
inches inches inches % seconds ipm volts ipm volts
16 GA
0.06
0.15 250
0.1
316 118 425 120
10 GA 220 121 296 122
3/16 0.2 152 123 168 123
1/4 0.5 72 125 96 125
3/8 0.7 48 130 52 128
1/2 0.18 300 1.2 23 134 32 131
5/8
Edge Start
19 137 20 136
3/4 14 140 15 140

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax125 and is the answer not in the manual?

Hypertherm Powermax125 Specifications

General IconGeneral
BrandHypertherm
ModelPowermax125
CategoryWelding System
LanguageEnglish

Related product manuals