EasyManuals Logo
Home>IBM>Laptop>5100

IBM 5100 Maintenance Analysis Procedures

IBM 5100
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #117 background imageLoading...
Page #117 background image
(
(
(
L M N
333
044
POWER MAP
PAGE
5
OF
-Power down.
5
-Disconnect keyboard cable at the
keyboard
(refer
to
204).
-Power up.
Is
the
measured
voltage
out
of
tolerance
now?
Y N
045
Short circuit
in
the keyboard
PC
board.
(refer
to
251).
046
Defective keyboard cable
(refer
to
204).
047
Go
to
Page
5,
Step
048,
Entry
Point
C.
048
(Entry
Point
C)
-Power down.
-Remove all the cards from the board.
(refer
to
209.)
-Power up.
Wait
30 seconds.
Does
fuse
F1
blow
or
does
power
drop
or
is
the
voltage
out
of
tolerance
now?
Y N
049
Defective card.
Power down and power up
as
you reinstall the
cards one at a time until the defective card
is
found.
050
Defective A 1 board.
F
2
051
MAP 0700-5
The power supply is working properly.
Are
you
missing
a
voltage
at
a
specific
device?
Y N
052
Defective A 1 board.
053
-Trace the circuit from that device
to
the power
supply
(refer
to
section
5,
power supply voltages).
12DEC75
PN
1608392
EC
829523
PEC
828851
MAP 0700-5