EVFU Select
The EVFU SELECT (Electronic Vertical Format Unit Select) option determines if
EVFU skips can be defined. An EVFU skip is an instruction to move the paper to a
specific location on a form. See the 6500 ASCII Programmer’s Reference Manual for
more information.
v Enable (the default). Defines EVFU skips.
v Disable. Does not define EVFU skips.
Upper Case Select
Controls how the printer handles lowercase characters it receives from the host
computer. When enabled, all characters will be printed in uppercase.
v Disable (the default). Prints lowercase characters received from the host
computer as lowercase, and prints uppercase characters received from the
computer as uppercase.
v Enable. Prints lowercase characters received from the host computer as their
corresponding uppercase equivalents; uppercase characters received from the
computer print as uppercase.
Slew Relative
“Slewing” is rapid vertical paper movement. This parameter determines the
number of lines slewed when an EVFU Slew Relative command is received.
v 1-16 Lines (the default). Slews 1-15 lines.
v 1-16 Lines. Slews 1-16 lines.
188 Infoprint 6500 User’s Manual