EasyManuals Logo
Home>IBM>Printer>6500

IBM 6500 User Manual

IBM 6500
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
Hex Transparent Control
This option allows you to enable (the default) or disable additional features that
are not available in standard IBM emulations. To access these features, send lead-in
character text commands in the data stream. You can also use ASCII codes X'80'
through X'9F' as control codes if configured to do so.
Lead-In Characters
The Lead-In Character commands must have a start and end code. Set 1 is the
factory default. Three sets (each containing a start and end code) are available:
v Set 1: start code = <% (default)
end
code = >
v Set 2: start code = ¬¬
end
code = $
v Set 3: start code = _%
end code = _
v User Defined
User Defined Codes
v Start Code 2: X'5F' (the default)
v Start Code 1: X'5F'
v Stop code: X'5B'
The codes can be set to X'40' - X'FF' range
Alternate Set 80 - 9F
This selection determines if ASCII codes X'80' through X'9F' will be used as control
codes or printed as standard printable characters.
v Printable (the default). Prints the alternate set as standard characters
v Control Code. Selects the alternate set to be used as printer control codes.
72 Infoprint 6500 User’s Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 6500 and is the answer not in the manual?

IBM 6500 Specifications

General IconGeneral
BrandIBM
Model6500
CategoryPrinter
LanguageEnglish

Related product manuals