Step 3 - JES2 Definition
This definition is not required if you are using VPS and using U1 - U9999 as the
printer ID.
RMT1 LUTYPE1,BUFSIZE=3840,LINE=1,NUMRD=0,NUMPR=1,NOCOMP,NOCMPCT,
SETUPHDR,CONSOLE (SETUPHDR=PDIR JES2 V3)
R1.PR1 CLASS=A,NOSEP,PRWIDTH=132,NOFCBLOD,WS=(W,R,Q,PMD,LIM,F,T/C,P),
CKPTPAGE=30
DESTID NAME=P6500,DEST=R1
Step 4 - Define to CICS or another application program
An application program must provide the SCS commands to control the printer.
CICS, VPS, and other applications support SCS as well as numerous application
programs, both customer written and vendor supplied. Refer to the vendor
documentation for defining an SCS printer to the program for its use. If there is no
specific information on the 6500–v you may use the IBM 4234 for reference.
Step 5 - Printer Settings
It is recommended that the following printer settings be changed from factory
default settings:
v Printer Control => Interface Selection => Coax
v Coax Interface => Format Control => Enable
278 Infoprint 6500 User’s Manual