Table 1. Features and operating specifications (continued)
Notes:
1. Power consumption and heat output vary depending on the number and type of optional features that are
installed and the optional power-management features that are in use.
2. These levels are measured in controlled acoustical environments according to the procedures specified by the
American National Standards Institute (ANSI) S12.10 and ISO 7779, and are reported in accordance with ISO
9296. Actual sound-pressure levels in a given location might exceed the average stated values because of room
reflections and other nearby noise sources. The declared sound-power levels indicate an upper limit, below which
a large number of computers will operate.
Models and optional devices
The storage subsystem components and configurations are explained in this topic.
The DS3500 storage subsystem controller cache size, partitions, and other features
vary depending on the model and optional devices. Table 2 shows the DS3500
models and options available at the time of publication. Contact your IBM
marketing representative or authorized reseller for more information about models
and options.
Table 2. DS3500 storage subsystem models and optional devices
DS3512 Dual Controller
v Two controllers each with 1 GB cache (2
GB total)
v Four 6 GB SAS ports
v Supports two host interface cards (must
be of same type)
DS3524 Single Controller
v One controller with 1 GB cache
v Two 6 GB SAS ports
v Supports one host interface card
DS3524 Dual Controller
v Two controllers each with 1 GB cache (2
GB total)
v Four 6 GB SAS ports
v Supports two host interface cards (must
be of same type)
DS3524 Dual Controller - DC power
v Two controllers each with 1 GB cache (2
GB total)
v Four 6 GB SAS ports
v Supports two host interface cards (must
be of same type)
The following optional features apply to all base configurations of the DS3500
storage subsystem:
v Host Interface Cards:
– 6 Gbps SAS 2-port daughter card
– 8 Gbps FC 4-port daughter card (includes two 8 GB SFP transceivers)
– 1 Gbps iSCSI 4-port daughter card (Copper)
– 10 Gbps iSCSI 2-port daughter card (Copper)
v Additional Hardware Options:
– Second controller (for single-controller base system)
6 IBM System Storage DS3500 and EXP3500 Storage Subsystem: Installation, User's, and Maintenance Guide