8. Touch the static-protective package that contains the host port adapter to any
unpainted metal surface on the storage subsystem; then, remove the adapter
from the package.
9. If you are replacing a failed host port adapter, skip to the next step.
Otherwise, install the host port cover that comes with the optional host port
adapter.
a. Place the alignment tab/edge inside the host port cutout.
b. Secure the host port cover with two screws.
10. Align the host port adapter as shown in the following illustration. The host
port will protrude slightly from the host port cover. Because the host port
cover cutout is a tight fit, you must apply slight pressure to get the port
connectors through the cutout.
Host port adapter
filler panel
Screws
Alignment tab
dg1fy160
Figure 96. Removing the host port adapter filler panel
Chapter 5. Replacing components 119