12. Type the following commands on the 7036-P16 command line using the information gathered in Step
1 to complete the IP Address configuration:
set config ip=[IP Address]
set config submask=[Subnet Mask]
set config gateway=[IP Gateway Address]
set config dns=[Name Server Address]
set config dhcp=off
set config hostname=[Host Name]
set config domain=[Domain Name]
13. As a precaution, you can deactivate the ping-ARP and RARP options. To deactivate the ping-ARP
and RARP options type the following commands:
set config Ping-ARP=off
set config RARP=off
14. If the user plans to use the Digi RealPort software on the host server to control all the 7036-P16
ports, then the system ports must be configured for use with the Digi RealPort software. Type the
following command: set port range=* dev=rp
15. Issue the reboot command to the 7036-P16 in order to permanently set the changes. Type the
following command: boot action=reset
When the 7036-P16 reboots, then the network configuration is complete.
The 7036-P16 can now be accessed through the Ethernet connection. The user can program other features
as required. See additional documentation on the 7036-P16 Software and Documentation CD.
Direct-attach configuration method
A regular tty terminal or a PC running a terminal emulation program, may be attached directly to any
one of the 16 ports and commands entered on the 7036-P16 command line to configure the 7036-P16 onto
the network.
This method requires the user to be in the same room as the 7036-P16. This method requires the user to
have a tty terminal or a PC available. This method requires a serial cable to connect the tty terminal or
PC to the server. This method is independent of the operating system installed on the server.
To configure the 7036-P16 device into the network using this method, do the following steps:
1. Gather the following information from the system or network administrator:
v MAC Address: [MAC Address] (MAC Address label is on the back of the 7036-P16)
v IP Address: [IP Address]
v Default Gateway: [IP Gateway Address]
v Name Server: [Name Server Address]
v Subnet Mask: [Subnet mask]
v Host Name: [Host Name]
v Domain Name: [Domain Name]
2. Connect the power cord from the 7036-P16 to a power source and power up.
3. Connect the serial cable from tty terminal to the 7036-P16.
4. Log in to the 7036-P16 as the root user, use the default password dbps.
5. After login, you can change the root password. Type:newpass
6. To view the current configuration, type: set config
7. Type the following commands on the 7036-P16 command line using the information gathered in Step
1 to complete the IP Address configuration:
set config ip=[IP Address]
set config submask=[Subnet Mask]
set config gateway=[IP Gateway Address]
102 Managing devices

Table of Contents

Other manuals for IBM Power 750 Express

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power 750 Express and is the answer not in the manual?

IBM Power 750 Express Specifications

General IconGeneral
BrandIBM
ModelPower 750 Express
CategoryServer
LanguageEnglish

Related product manuals