4. Connect an Ethernet cable between the port of the personal computer that is
configured in step 2 on page 160 and the technician port. After the connection
is made, the system will automatically configure the IP and DNS settings for
the personal computer if DHCP is available. If it is not available, the system
uses the values that you provided in step 2 on page 160.
5. After the Ethernet port of the personal computer is connected, open a
supported browser and browse to address http://install. (If you do not have
DCHP, open a supported browser and go to the following static IP address
192.168.0.1.) The browser is automatically directed to the initialization tool.
6. Follow the instructions that are presented by the initialization tool to configure
the system with a name and management IP address.
7. If you experience a problem during the process due to a change in system
states, wait 5 - 10 seconds. Then, either reopen the SSH connection or reload
the service assistant.
8. After you complete the initialization process, disconnect the cable between the
personal computer and the technician port.
What to do next
The system can now be reached by opening a supported web browser and
pointing it to http://management_IP_address.
Configuring a system to be NEBS-compliant
For operation in Network Equipment-Building System (NEBS) compliant
installations, the system can be configured to extend its operational temperature
range to meet NEBS operating temperature requirements.
Note: The system might not be able to save its cache and state data if the power
fails while it is operating within the extended temperature range. This is because
the battery capacity decreases as temperature rises. If the save of cache and state
data cannot be completed, an extended service action is required to recover the
system and data might be lost. Keep the temperature within the normal operating
range if possible, and maintain a reliable power supply.
v To extend the operational temperature range of all enclosures in the system to
meet NEBS operating temperature requirements, enter the following CLI
command:
chsystem -hightempmode on
After it is set, high_temp_mode is applied to all enclosures in the system.
Figure 144. Storwize V5030 technician port
Chapter 3. Configuring the system 161