Appendix B. UEFI/POST diagnostic codes
UEFI/POST diagnostic error codes can be generated when the server starts or
while the server is running. UEFI/POST codes are logged in the IMM event log in
the server.
For each event code, the following fields are displayed:
Event identifier
An identifier that uniquely identifies an event.
Event description
The logged message string that appears for an event.
Explanation
Additional information to explain why the event occurred.
Severity
An indication of the level of concern for the condition. The severity is
abbreviated in the event log to the first character. The following severities
can be displayed.
Table 42. Event severity levels
Severity Description
Informational An informational message is something that was recorded for
audit purposes, usually a user action or a change of states that is
normal behavior.
Warning A warning is not as severe as an error, but if possible, the
condition should be corrected before it becomes an error. It
might also be a condition that requires additional monitoring or
maintenance.
Error An error typically indicates a failure or critical condition that
impairs service or an expected function.
User response
The actions that you should take to resolve the event.
Perform the steps in the order shown until the problem is solved. After
you perform all of the actions that are described in this field, if you cannot
solve the problem, contact IBM Support.
Booting server to F1 setup menu
In additional to the normal process in booting the server to the F1 setup
menu (pressing F1 when <F1 Setup> is displayed), there are two other
ways for users to choose.
v Method 1
1. Proceed to the IMM2 website.
2. Select Server Management tab.
3. Select Server Power Action.
4. Select Boot Server to F1 Setup.
v Method 2
Use Advanced Settings Utility (ASU) program. Command line is shown
as follows: asu.exe set IMM.ForceBootToUefi enable
© Copyright IBM Corp. 2014 665

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M5 Type 5463 and is the answer not in the manual?

IBM System x3550 M5 Type 5463 Specifications

General IconGeneral
BrandIBM
ModelSystem x3550 M5 Type 5463
CategoryServer
LanguageEnglish

Related product manuals