Statement 34:
CAUTION:
To reduce the risk of electric shock or energy hazards:
v This equipment must be installed by trained service personnel in a
restricted-access location, as defined by the NEC and IEC 60950-1, First
Edition, The Standard for Safety of Information Technology Equipment.
v Connect the equipment to a properly grounded safety extra low voltage
(SELV) source. A SELV source is a secondary circuit that is designed so
that normal and single fault conditions do not cause the voltages to
exceed a safe level (60 V direct current).
v Incorporate a readily available approved and rated disconnect device in
the field wiring.
v See the specifications in the product documentation for the required
circuit-breaker rating for branch circuit overcurrent protection.
v Use copper wire conductors only. See the specifications in the product
documentation for the required wire size.
v See the specifications in the product documentation for the required
torque values for the wiring-terminal screws.
To remove a hot-swap dc power supply, complete the following steps:
1. Read the safety information that begins on page vii and “Installation
guidelines” on page 191.
2. If only one power supply is installed, turn off the server and peripheral devices
and disconnect all power cords.
3. If the server is in a rack, at the back of the server, pull back the cable
management arm to gain access to the rear of the server and the power
supply.
Important: Be sure to read the multilingual safety instructions on the CD that
comes with the server before you use the product.
Chapter 5. Removing and replacing server components 265