The cable must be securely attached at all connections. If the cable is attached
but the problem remains, try a different cable.
If you set the Ethernet controller to operate at 100 Mbps, you must use
Category 5 cabling.
If you directly connect two servers (without a hub), or if you are not using a
hub with X ports, use a crossover cable. To determine whether a hub has an X
port, check the port label. If the label contains an X, the hub has an X port.
v Determine whether the hub supports auto-negotiation. If it does not, try
configuring the integrated Ethernet controller manually to match the speed and
duplex mode of the hub.
v Check the Ethernet controller LEDs on the rear panel of the server. These LEDs
indicate whether there is a problem with the connector, cable, or hub.
The Ethernet link status LED is lit when the Ethernet controller receives a link
pulse from the hub. If the LED is off, there might be a defective connector or
cable or a problem with the hub.
The Ethernet transmit/receive activity LED is lit when the Ethernet controller
sends or receives data over the Ethernet network. If the Ethernet
transmit/receive activity is off, make sure that the hub and network are
operating and that the correct device drivers are installed.
v Check the LAN activity LED on the rear of the server. The LAN activity LED is
lit when data is active on the Ethernet network. If the LAN activity LED is off,
make sure that the hub and network are operating and that the correct device
drivers are installed.
v Check for operating-system-specific causes of the problem.
v Make sure that the device drivers on the client and server are using the same
protocol.
Results
If the Ethernet controller still cannot connect to the network but the hardware
appears to be working, the network administrator must investigate other possible
causes of the error.
Solving undetermined problems
If Dynamic System Analysis (DSA) did not diagnose the failure or if the server is
inoperative, use the information in this section.
About this task
If you suspect that a software problem is causing failures (continuous or
intermittent), see “Software problems” on page 174.
Corrupted data in CMOS memory or corrupted UEFI firmware can cause
undetermined problems. To reset the CMOS data, use the CMOS clear jumper (JP1)
to clear the CMOS memory and override the power-on password; see Table 2 on
page 30 for more information. If you suspect that the UEFI firmware is corrupted,
see “Recovering the server firmware (UEFI update failure)” on page 179.
If the power supplies are working correctly, complete the following steps:
Chapter 4. Troubleshooting 177