EasyManuals Logo
Home>IBM>Server>x3550 M4 Type 7914

IBM x3550 M4 Type 7914 User Manual

IBM x3550 M4 Type 7914
868 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #288 background imageLoading...
Page #288 background image
5. Insert the fan into the fan slot in the fan assembly bracket and press it down
until it is seated correctly in the slot and the fan connector is seated correctly in
the connector on the system board.
Note: Make sure that the newly-installed fan aligns horizontally with other
correctly-seated fans for proper installation.
6. Replace the cover (see “Replacing the cover” on page 209).
7. Slide the server into the rack.
Removing a power supply
Use this information to remove a power supply.
Figure 166. Fan installation
270 IBM System x3550 M4 Type 7914: Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3550 M4 Type 7914 and is the answer not in the manual?

IBM x3550 M4 Type 7914 Specifications

General IconGeneral
BrandIBM
Modelx3550 M4 Type 7914
CategoryServer
LanguageEnglish

Related product manuals