5. Use the thermal-grease syringe to place nine uniformly spaced dots of 0.02 mL
each on the top of the microprocessor.
Note: 0.01mL is one tick mark on the syringe. If the grease is properly applied,
approximately half (0.22 mL) of the grease will remain in the syringe.
Installing a memory module
The following notes describe the types of dual inline memory modules (DIMMs)
that the server supports and other information that you must consider when you
install DIMMs.
About this task
Microprocessor
0.02 mL of thermal
grease
Figure 119. Thermal grease distribution
Figure 120. Syringe
Chapter 2. Installing optional devices 115