18
7
FUNCTION MODE OPERATION
New2001
You can record the received signal whenever you want by
using the manual recording function.
This function can record the received signal for maximum
30 seconds.
The transmitted signal cannot be recorded.
The previously recorded signal will be overwritten when you
record the next audio using this function.
q Push F to enter the
function mode,
and then push /
 to select the
manual recording
function.
• “M-REC” appears.
w Push H/L•LOCK to
start recording.
• “REC” appears.
When the signal disappears, the
transceiver continues recording
without audio.
e Push F to stop the
recording.
The recording will automatically
stop after 30 seconds.
Manual recording
mode appears.
“REC” appears
while recording.
• Example— Manual recording
[Less than 30 seconds]
[More than 30 seconds]
Example: 20 seconds
30 seconds
When receiving a signal for 30
seconds or less, this function
records all contents.
30 seconds after you start the manual recording, the
recording will automatically stop.
These contents
will not be recorded.
Start manual
recording.
Start manual
recording.
Stop manual
recording.
Automatically stops
recording.
Manual recording function (Depending on versions)