Technical Specifications
39
Electrical Specifications
External Power Supply
Voltage
100 - 240 V AC
Frequency
47 - 63 Hz
Operating Temperature
0 to 40 °C (40 to 105 °F)
Relative Humidity
20 to 80% (non-condensing)
ECO Standard
CEC Level VI
Scanner
Voltage
24 V DC
Current
Max. 7.5 A
Illumination System
Light Source
White LEDs, tested according to
IEC 62471, no IR/UV emission
Warm Up Time
None
Temperature Dependency
None
Lamp Lifetime
50,000 hours typ. Lamps are
covered by the Extended Warranty
Option
Power Consumption
Sleep
< 0.5 W
Standby
1.5 W
Ready to Scan, Monitor on
40 W
Scanning
110 W