- 107 -
1. Please set the parameters according to the nameplate parameters of the
motor.
2. It needs accurate motor parameters to ensure the excellent control
performance of the vector control. Accurate parameter identification comes
from the correct setting of the rated motor parameters.
3. To ensure the control performance, please carry out motor
configurations in accordance with the standard adaptable motor of the
driver. If there is huge difference between the motor power and the power
of standard adaptable motor, the control performance of the driver will
decrease obviously.
Resvered
Factory default
value
F1-06
F1-09
Setup
range
D-axis
inductance
Factory default
value
Model dependent
F1-11
Setup
range
065535
Q-axis
inductance
Factory default
value
Model dependent
F1-12
Setup
range
065535
Stator
resistance
Factory default
value
Model dependent
F1-13
Setup
range
065535
unit
Factory default
value
Model dependent
F1-14
Setup
range
0012
Back EMF
Factory default
value
Model dependent
F1-15
Setup
range
065535V

Table of Contents

Other manuals for Inovance IS300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance IS300 Series and is the answer not in the manual?

Inovance IS300 Series Specifications

General IconGeneral
BrandInovance
ModelIS300 Series
CategoryServo Drives
LanguageEnglish

Related product manuals