- 107 -
1. Please set the parameters according to the nameplate parameters of the
motor.
2. It needs accurate motor parameters to ensure the excellent control
performance of the vector control. Accurate parameter identification comes
from the correct setting of the rated motor parameters.
3. To ensure the control performance, please carry out motor
configurations in accordance with the standard adaptable motor of the
driver. If there is huge difference between the motor power and the power
of standard adaptable motor, the control performance of the driver will
decrease obviously.
Resvered
Factory default
value
-
F1-06~
F1-09
Setup
range
-
D-axis
inductance
Factory default
value
Model dependent
F1-11
Setup
range
0~65535
Q-axis
inductance
Factory default
value
Model dependent
F1-12
Setup
range
0~65535
Stator
resistance
Factory default
value
Model dependent
F1-13
Setup
range
0~65535
unit
Factory default
value
Model dependent
F1-14
Setup
range
00~12
Back EMF
Factory default
value
Model dependent
F1-15
Setup
range
0~65535V