- 106 -
speed-up/speed-down time and the setup speed-up/speed-down time.
There are totally four groups o speed-up/speed-down time for selection.
Group 1: F0-17 and F0-18;
Group 2: F8-03 and F8-04;
Group 3: F8-05 and F8-06;
Group 4: F8-07 and F8-08;
It can select speed-up/speed-down time via the multifunctional digital input
terminals (F4-00 to F4-08).
Group F1 Motor Parameters
Motor type
selection
Factory default
value
2
0 Common asynchronous motor
1 Variable frequency asynchronous motor
F1-00
Setup
range
2 Permanent magnetic synchronous motor
Rated power
Factory default
value
Model dependent
F1-01
Setup
range
0.4kW~1000.0kW
Rated voltage
Factory default
value
Model dependent
F1-02
Setup
range
0V~440V
Rated current
Factory default
value
Model dependent
F1-03
Setup
range
0.00A~655.35A
Rated
Frequentcy
Factory default
value
Model dependent
F1-04
Setup
range
0.00Hz~ maximum frequency
Rated rotation
speed
Factory default
value
Model dependent
F1-05
Setup
range
0rpm~30000rpm