- 22 -
2.7.4 Storage of Driver
Upon acquiring the driver, the user shall pay attention to the following points
regarding the temporary and long-term storage of the driver:
1) Pack the driver with original package and place back into the packing box
of our company.
2) Long-term storage will degrade the electrolytic capacitor. Thus, the
product shall be powered up once every 2 years, each time lasting at least
five hours. The input voltage shall be increased slowly to the rated value
with the regulator.
2.8 Instructions on Warranty of Driver
Free warranty only applies to the driver itself.
1) Our company will provide 18-month warranty (starting from the
leave-factory date as indicated on the barcode) for the failure or damage
under normal use conditions. If the equipment has been used for over 18
months, reasonable repair expenses will be charged.
2) Reasonable repair expenses will be charged for the following situations
within 18 months:
a The equipment is damaged because the user fails to comply with
the requirements of the user’s manual;
b Damage caused by fire, flood and abnormal voltage;
c Damage caused when the driver is used for abnormal function.
The service expenses will be calculated according to the standard of the
manufacturer. If there is any agreement, the agreement shall prevail.
2.9 Prototyping Guide
Three control modes are available, namely, V/F and VC.
When selecting driver, it must firstly make clear the technical requirements of
the system for variable frequency speed adjustment and specific details
regarding the applications and load characteristics of the driver, and select the
model and determine the operating mode through taking into overall
consideration the adaptable motor, output voltage, rated output current and
other factors.
The basic principle is that the rated load current of the motor shall not exceed
the rated current of the inverter. Generally, the selection is based on the
adaptable motor capacity as specified in the instruction manual. Due attention

Table of Contents

Other manuals for Inovance IS300 Series

Question and Answer IconNeed help?

Do you have a question about the Inovance IS300 Series and is the answer not in the manual?

Inovance IS300 Series Specifications

General IconGeneral
BrandInovance
ModelIS300 Series
CategoryServo Drives
LanguageEnglish

Summary

Chapter 1 Safety and Precautions

1.1 Safety Precautions

Lists safety precautions before, during installation, and wiring.

1.2 Precautions

General precautions for motor insulation, thermal protection, and heating.

Chapter 2 Product Information

2.4 Technical Specifications

Provides detailed technical specifications for the servo driver functions.

2.7 Routine Repair and Maintenance of Servo Driver

Chapter 3 Mechanical and Electric Installation

3.1 Mechanical installation

Covers installation environment requirements like temperature and mounting.

3.2.5 Control terminals and connection

Explains the layout and function of control circuit terminals.

Operation and Display

4.6 Automatic Tuning of Motor Parameters

Procedures for automatic tuning of motor parameters for vector control.

Group F2 Vector Control Parameters

Group F5 Output Terminal

Group F8 Auxiliary Function

Group F9 Fault and Protection

Parameters for configuring motor overload, stall, and transient protection.

Chapter 6 Parameter Description

Chapter 7 Servo Pump Commissioning Steps and Prototyping of servo pump optional parts

7.2 Servo Pump Commissioning Steps

Detailed steps for servo pump commissioning.

Chapter 8 EMC (Electromagnetic Compatibility)

Failure Diagnosis and Solution

Chapter 9 Failure Diagnosis and Solution

Guides users on diagnosing and resolving common driver faults and errors.

9.2 Common Fault and Resolution

Provides a table of common faults, their causes, and solutions.

Group F1 Motor Parameters

Group F2 Control Parameters

Parameters for vector control, including speed loop gains and integration times.

Group F3 V/F Control Parameters

Parameters for V/F control, such as V/F curve setup and torque boost.

Group F4 Input Terminal

Group F6 Start/Stop Control

Appendix 2 Shortcut menu parameters table

uF2-00 Speed loop proportional gain 1

Parameter for setting the speed loop proportional gain (P1).