- 113 -
Setup range 0 ~ 65535
Note: When the driver controls the speed sensor vector control, it must set
the pulse number of the encoder correctly, or the motor will run abnormally.
If normal operation cannot be realized after correct pulse number of the
encoder is set, exchange the connection positions of Phase A and Phase B
of the encoder.
Reserved
Factory default
value
F2-12
Setup
range
D axis current
loop
Factory default
value
50
F2-13
Setup
range
065535
D-axis current
loop Ki
Factory default
value
50
F2-14
Setup
range
065535
D -axis current
loop Kp
Factory default
value
50
F2-15
Setup
range
065535
D-axis current
loop Ki
Factory default
value
50
F2-16
Setup
range
065535
When the automatic tuning of the motor is normally completed, the setup
values of F2-13 to F2-16 will be automatically set up.
Each time when the rated power of the motor F1-01 is changed, the driver will
automatically recover the parameter values of F2-13F2-16 to the default
standard motor parameters.
If it is impossible to tune the motor on the site, the user can manually
input the parameters by referring to the known parameters of the motors of
the same type.
F2-17
SoftPwm
selection
Factory default
value
0

Table of Contents

Other manuals for Inovance IS300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance IS300 Series and is the answer not in the manual?

Inovance IS300 Series Specifications

General IconGeneral
BrandInovance
ModelIS300 Series
CategoryServo Drives
LanguageEnglish

Related product manuals