- 50 -
display flashes and prompts whether to save the parameter into shortcut menu.
Press ENTER key for confirmation, the display stops flashing, and the
operation is completed. Press PRG key to cancel, the display stops flashing,
and the operation is cancelled.
2) Modification of shortcut parameters
Run or Stop
Display
Fig.4-5 Example of Modification of Shortcut Parameters
Run or Stop Desplay:
Note: In Stop or running display interface, press QUICK key to enter shortcut
key, and select different shortcut parameters with UP/DOWN key. Then press
ENTER key to enter next level of menu. At this time the modification method of
shortcut parameter is the same as that of the parameters in common level 3
menu. To return to the upper level display, press QUICK key, and the
modified parameters will not be saved.
3) Delete shortcut parameter item:
Fig.4-6 Deletion of Shortcut Menu
Note: Press PRG key in shortcut menu, the display flashes and prompts
whether to delete the parameter. Press ENTER key for confirmation, the
display stops flashing and the deletion operation is completed. Press QUICK
key, the display stops flashing, and the deletion operation is canceled. If the
last shortcut parameter is deleted, “NULL” will be displayed upon deletion,
indicating that the shortcut menu is NULL.
Flash display