System degraded:
Redundancy loss, such as power-supply or fan. Applies only if the
associated platform sub-system has redundancy capabilities.
Fan warning or failure when the number of fully operational fans is
more than minimum number needed to cool the system.
Non-critical threshold crossed – Temperature (including HSBP
temp), voltage, input power to power supply, output current for
main power rail from power supply and Processor Thermal Control
(Therm Ctrl) sensors.
Power supply predictive failure occurred while redundant power
supply configuration was present.
Unable to use all of the installed memory (one or more DIMMs
failed/disabled but functional memory remains available)
Correctable Errors over a threshold and migrating to a spare DIMM
(memory sparing). This indicates that the user no longer has spared
DIMMs indicating a redundancy lost condition. Corresponding DIMM
LED lit.
Uncorrectable memory error has occurred in memory Mirroring
Mode, causing Loss of Redundancy.
Correctable memory error threshold has been reached for a failing
DDR4 DIMM when the system is operating in fully redundant RAS
Mirroring Mode.
Battery failure.
BMC executing in uBoot. (Indicated by Chassis ID blinking at Blinking
at 3Hz). System in degraded state (no manageability). BMC uBoot is
running but has not transferred control to BMC Linux*. Server will be
in this state 6-8 seconds after BMC reset while it pulls the Linux*
image into flash
BMC booting Linux*. (Indicated by Chassis ID solid ON). System in
degraded state (no manageability). Control has been passed from
BMC uBoot to BMC Linux* itself. It will be in this state for ~10-~20
seconds.
BMC Watchdog has reset the BMC.
Power Unit sensor offset for configuration error is asserted.
HDD HSC is off-line or degraded.