Intel® Server Board S1200SP Family Technical Product Specification
43
6.1.2 Non-IPMI Features
The BMC supports the following non-IPMI features. This list does not preclude support for future
enhancements or additions.
• In-circuit BMC firmware update
• Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality.
• Chassis intrusion detection
• Basic fan speed control using Control version 2 SDRs
• Fan redundancy monitoring and support
• Power supply redundancy monitoring and support
• Hot-swap fan support
• Acoustic management: Support for multiple fan profiles
• Signal testing support: The BMC provides test commands for setting and getting platform signal states.
• The BMC generates diagnostic beep codes for fault conditions.
• System GUID storage and retrieval
• Front panel management: The BMC controls the system status LED and chassis ID LED. It supports secure
lockout of certain front panel functionality and monitors button presses. The chassis ID LED is turned on
using a front panel button or a command.
• Power state retention
• Power fault analysis
• Intel
®
Light-Guided Diagnostics
• Power unit management: Support for power unit sensor. The BMC handles power-good dropout
conditions.
• DIMM temperature monitoring: New sensors and improved acoustic management using closed-loop fan
control algorithm taking into account DIMM temperature readings.
• Address Resolution Protocol (ARP): The BMC sends and responds to ARPs (supported on embedded NICs).
• Dynamic Host Configuration Protocol (DHCP): The BMC performs DHCP (supported on embedded NICs).
• Platform environment control interface (PECI) thermal management support
• E-mail alerting
• Embedded web server:
• Integrated KVM
• Integrated Remote Media Redirection
• Lightweight Directory Access Protocol (LDAP) support
• Intel
®
Intelligent Power Node Manager support
6.2 Basic and Advanced Features
The following table lists basic and advanced feature support. Individual features may vary by platform. See the
appropriate Platform Specific EPS addendum for more information.
Table 12. Basic and Advanced Features
In-circuit BMC Firmware Update
Chassis Intrusion Detection
Fan Redundancy Monitoring