Intel® Server Board S1200SP Family Technical Product Specification
105
Table 60. Integrated BMC Core Sensors
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor
Type
Event/
Reading
Type
Event Offset Triggers
Contrib.
To System
Status
Assert/
De-assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Power Unit Status
(Pwr Unit Status)
01h
All
Power
Unit
09h
Sensor
Specific
6Fh
00 - Power down
OK
As and De
Trig
Offse
t
A
X
02 - 240 VA power
down
Fatal
04 - A/C lost
OK
05 - Soft power
control failure
Fatal
06 - Power unit failure
Power Unit
Redundancy1
(Pwr Unit Redund)
02h
Chassis-
specific
Power
Unit
09h
Generic
0Bh
00 - Fully Redundant
OK
As
Trig
Offse
t
M
X
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
sufficient resources.
Transition from full
redundant state.
Degraded
04 Non-redundant:
sufficient resources.
Transition from
insufficient state.
Degraded
05 - Non-redundant:
insufficient resources
Fatal
06 Redundant:
degraded from fully
redundant state.
Degraded
07 Redundant:
Transition from non-
redundant state.
Degraded
IPMI Watchdog
(IPMI Watchdog)
03h
All
Watchd
og 2
23h
Sensor
Specific
6Fh
00 - Timer expired,
status only
OK
As
Trig
Offse
t
A
X
01 - Hard reset
02 - Power down
03 - Power cycle
08 - Timer interrupt
Physical Security
04h
00 - Chassis intrusion
Degraded
As and De
A
X