P/N 146550999-1 • REV C • ISS 30APR12 3 / 36
10
JA
JT
3
6
4
5
Ra
Rt
Alarm (1)
Tamper (3)
A
larm zone (2)
12
Alarm
GND
+1
2V
134
5
26
7
8
11
JT JA
1K
22K
47K
56K
1K
22K
47K
56K
1
2
1
2
1
2
3
4
5
6
1
2
1
2
SW1 - Generic settings
LED ON
Remote OFF
Not used
Positive Polarity
LED OFF
Remote ON
Negative Polarity
Range
4
1 .
m
(
3ft
)
12
40 .
m
(
ft
)
9
30 .
m
(
ft
)
6
20 .
m
(
ft
)
13
ON
123456
JT JA
SW1
14
Single zone EOL
Zone state Value Default
Tamper (short) 0 0
Normal Rt 4.7 k
Alarm Rt+Ra 9.4 k
Tamper (open)
EN: Installation Sheet
Description
DD1012(-D) and DD1012PI are dual motion sensors. They
combine the patented PIR mirror optics technology with the
patented Range Controlled Radar technology.
The DD1012PI is designed to be immune up to certain size
and build of pets. Pets up to 18 kg (about 35 cm height)
normally do not cause any problems in standard application
unless they are able to move higher than 35 cm from the floor
in the detection field of view.
Installation guidelines
See Figure 1.
The detector is intended to be mounted on walls but can also
be mounted on ceilings by using a mounting bracket.
Use the following guidelines to determine the best location to
install the detector.
Mount the detector so the expected movement of an
intruder is across the detection pattern (see Figure 3).
Mount the detector at a stable surface at a height between
1.8 m and 3.0 m (5.9 and 9.8 ft.) from the floor.
Do not mount the detector within 0.5 m (1 ft. 8 in.) of
metallic objects or within 1.5 m (4 ft. 11 in.) of fluorescent
lights.
Do not place objects in front of the detector that may
prevent a clear line of sight.
Place detectors at least 6 m (19 ft. 8 in.) apart, and use
the short-range setting to avoid interference, when
mounting detectors face to face.
The dual technology processing of this detector is very
resistant to false alarm hazards. However, avoid potential
causes of instability, such as:
PIR hazards:
Direct sunlight on the detector
Heat sources within the detector field of view

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix DD1012 and is the answer not in the manual?

Interlogix DD1012 Specifications

General IconGeneral
BrandInterlogix
ModelDD1012
CategorySecurity Sensors
LanguageEnglish

Related product manuals