Basic Operation
4. After the parameter settings are complete, press [Enter].
The default communication method is USB. If other communication method
is selected, the related parameters need to be set. For detailed parameter
description, refer to 2.6 Remote Interface Connection.
The instrument supports the non-standard RS-232 and GPIB interfaces, and
the configuration items in the menu are dynamically displayed according to
the interface user selected.
5.10 Set Parallel Operation Mode (Parallel)
This menu item is used to control whether the instrument is working in single
mode or in parallel mode. This chapter takes three instruments (with operation
panel) as an example to describe how to parallelize the single units and how to
return from parallel mode to single mode.
The IT6000C series power supply supports multiple instruments to work in par-
allel mode to provide more power and current output capability.
Configure the Menu Item
1. Press the composite keys [Shift]+[P-set] (System) on the front panel to en-
ter the system menu.
2. Press the Up/Down key or turn the knob to select the Parallel and press
[Enter].
3. Press the Left / Right key or turn the knob to adjust the value of this
parameter.
Single: Default value, indicates that the instrument is in single mode.
Master: Indicates that the current single unit is set to master in parallel
mode. When set to Master, you also need to set the number of slaves to
be mounted for the master, so you need to set the value of the Total pa-
rameter. For example, setting Total = 3 means that the total number of
units in the parallel relationship is 3.
In the parallel mode, you only need to operate the master. Synchro-
nous operations on other slaves are implemented by operating the
master.
Slave: Indicates that the instrument is set to the slave in parallel mode.
Copyright © Itech Electronic Co., Ltd.
161

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6000C Series and is the answer not in the manual?

ITech IT6000C Series Specifications

General IconGeneral
BrandITech
ModelIT6000C Series
CategoryPower Supply
LanguageEnglish

Related product manuals