EasyManuals Logo
Home>ITech>Power Supply>IT6000C Series

ITech IT6000C Series User Manual

ITech IT6000C Series
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #220 background imageLoading...
Page #220 background image
Technical Specification
Parameter IT60012C-300-150
Command Response Time
2mS
Power Factor 0.99
Storage Temperature
-10℃~70
Protective Function
OVP, OCP, OPP, UVP, UCP, OTP, Vsense protection
Standard Interface
Standard: USB, CAN, LAN, VCP; optional: GPIB, analog card (in-
cludes RS232), fiber optic socket
Isolation ( output to ground)
1000V
Working Temperature
050
Dimension ( mm) 483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
30KG
Note: 1. Models without emergency stop module (i.e. AC contactor not included), other AC input
voltage ranges are required for customization. Models without emergency stop module and as-
sembled to the cabinet, with AC input voltage in the range of 198~264V, need to be customized
while derating by 50%. Models with emergency stop module (including AC contactor) only sup-
port 380VAC±10% for standard AC input voltage, 480VAC±10% voltage is required for
customization.
6.1.2.3 IT6018C-300-225
Parameter IT6018C-300-225
Rated value
Output Voltage
0300V
( 0 -50 ) Output Current
-225225A
Output Power
-1818kW
Output Resistance
0
Line Regulation Voltage
≤0.01%FS
±(of Output+Offset)
Current ≤0.05%FS
Load Regulation Voltage
≤0.02%FS
±(of Output+Offset)
Current ≤0.05%FS
Setup Resolution
Voltage
0.01V
Current 0.01A
Power 0.001kW
Resistance 0.001Ω
Read Back Resolution
Voltage
0.01V
Current 0.01A
Copyright © Itech Electronic Co., Ltd.
208

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6000C Series and is the answer not in the manual?

ITech IT6000C Series Specifications

General IconGeneral
BrandITech
ModelIT6000C Series
CategoryPower Supply
LanguageEnglish

Related product manuals