Technical Specification
Parameter IT6012C-500-80
Dimension ( mm) 483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
30KG
Note: 1. Models without emergency stop module (i.e. AC contactor not included), other AC input
voltage ranges are required for customization. Models without emergency stop module and as-
sembled to the cabinet, with AC input voltage in the range of 198~264V, need to be customized
while derating by 50%. Models with emergency stop module (including AC contactor) only sup-
port 380VAC±10% for standard AC input voltage, 480VAC±10% voltage is required for
customization.
6.1.3.3 IT6018C-500-120
Parameter IT6018C-500-120
Rated value
Output Voltage
0~500V
( 0 ℃-50 ℃) Output Current
-120~120A
Output Power
-18~18kW
Output Resistance
0~1Ω
Line Regulation Voltage
≤0.01%FS
±(%of Output+Offset)
Current ≤0.05%FS
Load Regulation Voltage
≤0.02%FS
±(%of Output+Offset)
Current ≤0.05%FS
Setup Resolution
Voltage
0.01V
Current 0.01A
Power 0.001kW
Resistance 0.001Ω
Read Back Resolution
Voltage
0.01V
Current 0.01A
Power 0.001kW
Resistance 0.001Ω
Setup Accuracy Voltage
≤0.02% + 0.02%FS
( within 12 months, 25℃
±5℃)
Current ≤0.1% + 0.1%FS
±(%of Output+Offset)
Power ≤0.5% + 0.5%FS
Resistance ≤1% + 1%FS
Read Back Accuracy Voltage
≤0.02% + 0.02%FS
Copyright © Itech Electronic Co., Ltd.