Technical Specification
Parameter IT6006C-800-25
Protective Function
OVP, OCP, OPP, OTP and Vsense reversed protection
Standard Interface
Standard: USB, CAN, LAN, VCP; optional: GPIB, analog card (in-
cludes RS232), fiber optic socket
Isolation ( output to ground)
1500V
Working Temperature
0~50℃
Dimension ( mm) 483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
20KG
6.1.4.2 IT6012C-800-50
Parameter IT6012C-800-50
Rated value
Output Voltage
0~800V
( 0 ℃-40 ℃) Output Current
-50~50A
Output Power
-12000~12000W
Output Resistance
0~1Ω
Line Regulation Voltage
≤0.01%FS
±(%of Output+Offset)
Current ≤0.05%FS
Load Regulation Voltage
≤0.02%S
±(%of Output+Offset)
Current ≤0.05%FS
Setup Resolution
Voltage
0.01V
Current 0.001A
Power 0.001kW
Resistance 0.01Ω
Read Back Resolution
Voltage
0.01V
Current 0.001A
Power 0.001kW
Resistance 0.01Ω
Setup Accuracy Voltage
≤0.02% + 0.02%FS
( within 12 months, 25℃
±5℃)
Current ≤0.1% + 0.1%FS
±(%of Output+Offset)
Power ≤0.5% + 0.5%FS
Resistance ≤1% + 1%FS
Read Back Accuracy Voltage
≤0.02% + 0.02%FS
Copyright © Itech Electronic Co., Ltd.
179