Source Subsystem
Copyright © ITECH Electronic Co., Ltd. 42
Chapter9 Source Subsystem
These commands control the input of the electronic load. The INPut and
OUTput commands are equivalent. INPut, CURRent, RESistance and
VOLTage commands program the actual input current, resistance, and voltage.
[SOURce:]INPut
These commands enable or disable the electronic load inputs. The state of a
disabled input is a high impedance condition.
Command Syntax [SOURce:]INPut[:STATe] <bool>
Parameters 0 | 1 | OFF | ON
*RST Value OFF
Examples INP 1
Query Syntax INPut[:STATe]?
Returned Parameters 0 | 1
Related Commands *RCL *SAV
[SOURce:]INPut:SHORt
This command programs the specified electronic load module to the maximum
current that it can sink in the present operating range.
Command Syntax [SOURce:]INPut:SHORt[:STATe] <bool>
Parameters 0 | 1 | OFF | ON
*RST Value OFF
Examples INP:SHOR 1
Query Syntax INPut:SHORt:STATe?
Returned Parameters 0 | 1
Related Commands INP
[SOURce:]INPut:TIMer
These commands enable or disable the load on timer.
Command Syntax [SOURce:]INPut:TIMer[:STATe] <bool>
Parameters 0 | 1 | OFF | ON
*RST Value OFF
Examples INP:TIM 1
Query Syntax INPut:TIMer[:STATe]?
Returned Parameters 0 | 1
Related Commands INP:TIM:DEL
[SOURce:]INPut:TIMer:DELay
This command specifies the load on timer.
Command Syntax [SOURce:]INPut:TIMer <NRf+>
Parameters 1 to 60000s | MINimum | MAXimum | DEFault
Unit seconds
*RST Value 10
Examples INP:TIM:DEL 5