9 LUBRICATION & MAINTENANCE
9.28 RADIATOR DIESEL MACHINE
Check Engine Coolant Level
(a) The level of coolant in the expansion tank
should be between the MAX and MIN level
indicators when cold.
(b) If topping up is required, remove the plastic
cap and top up using the correct anti-freeze
mixture.
(c) Replace the plastic cap when finished.
Changing Coolant
(a) To drain coolant, open cock on engine block
and remove hose from radiator.
(b) Close drain cock on engine block and
replace hose back on to radiator. Ensure all
hose clips are tight.
(c) Refill the cooling system with the correct anti-
freeze mixture. Fill system through expansion
tank.
(d) The level of coolant in the expansion tank
should be between the MAX and MIN level
indicators when cold.
(e) Run the engine for approximately 5 minutes
or until the thermostat opens.
(f) Check level of coolant in expansion tank and
top up if necessary
Contact with anti-freeze can damage your skin.
Use gloves when working with anti-freeze. If
you come in contact with anti-freeze, wash it off
immediately.
Dispose of used anti-freeze in accordance with
local regulations.

Table of Contents

Other manuals for Jacobsen G-Plex III

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jacobsen G-Plex III and is the answer not in the manual?

Jacobsen G-Plex III Specifications

General IconGeneral
BrandJacobsen
ModelG-Plex III
CategoryLawn Mower
LanguageEnglish

Related product manuals