29
XClearray™ operates automatically and is dependent on pump
activation (or the ltration pump, where present) during the l-
tering cycle, it remains o when the hydromassage, blower or even
just the spotlight are on (as it is presumed that there is somebody
in the tub); Clearray™ (where a ltering cycle is active) begins oper-
ating once again 40 minutes subsequent to switching o the afore-
mentioned functions.
Rapid Filtering (“Boost”)
( “hydro” and “hydro+blower” versions only)
This is recommended after intensive use of the hot tub and/or is as-
sociated with chemical treatment of the water, to favour the disso-
lution of substances used for disinfection.
XTo activate this function, press and hold down the “Pump”
key for 5 seconds. The display will show the message boo.
XThe operation lasts 45 minutes (this time period cannot be
modied) during which the pump is activated together with
Clearray™ (where present).
NOTES:
- If the heater is on, it will continue to run normally, unless the sys-
tem is congured for limitation of electrical consumption.
- the ltration pump is activated in “blower” models.
XThe function stops:
- when the aforementioned time expires
- when another function is activated.
- pressing the key Pump” again
.
NOTE: if you need to activate the anti-freeze protection during rap-
id ltering, rapid ltering will be stopped to allow the anti-freeze
protection to be started.
Hydromassage activation
XThis function is activated by pressing the “Pump” key or,
in some models, with the key :
In “hydro with heater” and “hydro +blower with heater”
models, the rst time the key is pressed starts the pump at a
low speed (if not already on to heat the water or for ltration),
the second time starts the high speed, and the third time
turns it o.
In “hydro with heat exchanger” models, the hydromassage
pump is turned on by the key
whereas the key “ turns
the ltering pump on and o (if not already on to heat the wa-
ter or for ltering).
In “hydro+blower with heat exchanger” models, the oper-
ation is as follows:
- the rst time the key is pressed turns on the ltering pump
(if not already on to heat the water or for ltering);
- the second press turns on the hydro pump;
- the third time the key is pressed turns o the ltering pump
(not available while heating the water or ltering);
- the fourth press turns o the hydro pump;
In “blower” models, the key turns the ltering pump on
and o (if not already on to heat the water or for ltering).
NOTES
The function turns o automatically after 20 minutes (if not turned
o by the user).
Blower activation (where present)
XPress the key “Blower” to activate the air compressor
(the LED comes on).
XThe blower can be activated either in conjunction with, or
separately from, the pump (when the system turns on, the blow-
er is always o).
XThe blower stays on for 20 minutes. It can be shut o before that
by pressing the key again.
XIf you want to use the blowers for aroma therapy (if installed),
insert the perfume cartridge in the compartment located under
the cover; once this cartridge is nished, it can be replaced with
a new one (cartridges are available from authorised Jacuzzi® deal-
ers and service centres).
CAUTION: Replace used cartridges when the blower is o.
Underwater spotlight
XPress the key “Light” to activate the spotlight located on
the wall of the tub (the LED comes on).
XThe spotlight will stay on for two hours, but it can be turned
o before that by pressing the key again. Refer to the user’s man-
ual for the operation of the various sequences of colours.
Temporary shutdown of system (stand-by)
This function lets you suspend operation of all system devices for a
period of 60 minutes (this value cannot be changed) so that you
can perform routine maintenance without having to disconnect
the power supply.
CAUTION
If you need to access the electronic parts, parts that are
normally powered, or the rotating parts of the pumps,
you must disconnect the electric power by turning o
the all-pole circuit breaker.
XTo activate the function, press and hold the “Light”
key
for about 8 seconds: the display will show the message “Sby” fol-