31
Troubleshooting
(also refer to the chapter on abnormal operating conditions)
PROBLEM PROBABLE CAUSE SOLUTION
Dirty water
Filter clogged Clean or replace lter
Insucient water treatment See chapter on water treatment
High content of solid material in water
Improper maintenance See the instructions regarding
Maintenance
Excessive water consumption Leak on delivery line, Repair the leak
outlet line, connections
Excessive evaporation and/or Use the hot tub cover
water overow Set a water temperature set point
lower
Low water ow Low water level Fill until covering
from the hydromassage nozzles the highest nozzles
Filter clogged Clean or replace lter
Adjustable jets partially closed Open the jets
Suction or drain pipes *
partially clogged
Pump operates at a *
speed that is too low
Pump gaskets worn or *
damaged
Voltage too low Contact an electrician or
the electric power utility
No water ow No current Turn main switches ON
Pump o Press the button
or
Motor not connected Check the motor connection
Main switch turned o Turn on the switch
Residual current operated circuit breaker Reset the RCCB
(RCCB) has tripped
Faulty pump or motor *
Pump and motor noisy Filters clogged Clean the lters
Water leakage on suction Find and repair leaks