S1 DIP
Switch #
OFF ON
7
No solar system installed.
Air temperature is
displayed.
Changes air sensor to solar
sensor. Air temperature
no longer displayed.
Adjustable Freeze Kit
must be added for freeze
protection.
8
After thermostat setting
has been reached, heater
will remain OFF for three
(3) minutes.
Heat Pump installed; after
thermostat setting has
been reached, heater will
remain OFF for five (5)
minutes.
S2 DIP
Switch #
OFF ON
1
The AquaLink
®
RS will
be able to control a Solar
Heating system (If a solar
sensor is connected to the
solar sensor input)
The AquaLink RS will be
able to control a Heat
Pump. (The AquaLink RS
will not be able to control
a Solar Heating system.)
6.3 DIP Switch Settings for Solar/Heat Pump
This table shows how to congure the system for SOLAR PRIORITY or HEAT
PUMP PRIORITY.
DIP
S2-1
GREEN 10-PIN
TERMINAL
BAR
RS485 HEAT
PUMP
DESCRIPTION
OFF No sensor
installed
Not connected In this configuration there
is no Solar Heating and
no Heat Pump. Extra
AUX is available.
OFF Sensor
installed
Not connected In this configuration there
is Solar Heating and
there is Solar Priority.
There is no Heat Pump.
Jandy
®
AquaLink
®
RS Conversion Kit

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy AquaLink RS Conversion Kit and is the answer not in the manual?

Jandy AquaLink RS Conversion Kit Specifications

General IconGeneral
BrandJandy
ModelAquaLink RS Conversion Kit
CategoryNetwork Hardware
LanguageEnglish

Related product manuals